Ul rated assemblies database. On-demand Webinar 5G and 802.
Ul rated assemblies database From the homepage, select Products, Systems or Assemblies > Building or Fire Systems > Fire Rated Walls, Floors, Beams and Columns Find and download resources for STC rated wall assemblies for your construction project. " Assembly performance under fire. Opening protectives Fire-resistance rated glazing. Aug 14, 2020 · Design No. com The fire-resistance rated wall assemblies published under the U, V and W series of designs on the UL Online Certifications UL iQ Databases. There are no code requirement related to the finish rating. UL certifies windstorm rated doors, hardware and other building assemblies for use in these applications. design number, such as UL U405 and nothing more. and alternate methods of construction. We have provided details on the plans for a U465 wall assembly. ul. Search by assembly number UL Product Spec™ also allows you to easily access designs when the design number is known. I have had it engrained in me that you cannot add or subtract to a UL listing as now the assembly is no longer listed,at It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. , Oct. Jun 27, 2023 · V438 | This UL design has multiple installation options for 1- to 4-hr. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products. UL Product iQ® Database, is an online search engine platform that helps users find UL Listed and UL Certified products, components and materials. What can I change in UL fire-rated wall assemblies without impacting the assigned fire rating? Windstorm rated assemblies - Concern about potential damage to building exteriors caused by hurricanes and tornadoes has resulted in regulations being adopted to provide protection from wind-borne debris. (See Items 6E and 7A) This design was evaluated using a load design method other than the Limit States Design Our Standards Catalog provides a list of UL Standards, Outlines, Certification Database — UL Product iQ® In this e-book, you will learn five tips to efficiently and cost-effectively transition from UL 508 to UL/CSA/IEC 61010-2-201 for industrial power supplies. These assemblies are intended Oct 29, 2019 · UL Product iQ offers the best of UL’s Online Certifications Directory and UL Product Spec, all in a single database for the U. Where do estimators go to find out what materials were used in the tested assembly? Windstorm rated assemblies Windstorm Rated Assemblies (ZHLA) — This category covers complete assemblies of products and materials that have been investigated to specific test standards and protocols for specific performance ratings. This statement means that the optional metric was not determined for the assembly. UL’s iQ™ family of 12 different material and component databases allows you to easily find, verify and specify UL Certified materials and components, enabling you to spend less time searching and more time innovating. All UL-approved partition designs are minimum requirements. V477 July 01, 2013 Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr (See Items 4 & 5) 1. Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. 7 %µµµµ 1 0 obj >/Metadata 1140 0 R/ViewerPreferences 1141 0 R>> endobj 2 0 obj > endobj 3 0 obj >/ExtGState >/ProcSet[/PDF/Text/ImageB/ImageC/ImageI USG Assembly Builder™ provides expertise on rated assemblies, giving architecture and construction professionals design accuracy in a fraction of the time. Fire-resistance rated glazing tested as part of a fire-resistance rated wall assembly in accordance with the Standard for Fire Tests of Building Construction and Materials, UL 263 (ASTM E119), is covered under the Fire-resistance Rated Glazing Materials category. This document is intended toaid in the design of various woodframe walls and w-ood - frame floor/ceiling assemblies, where such assemblies are required by code to be fire -resistance-rated. Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire-resistance Ratings - ANSI/UL 263 Design No. Finish Rating — 23 Min (See Items 5 or 5A and 7), 20 Min. Only products which bear UL's Mark are considered Certified. Whether you need exterior design detail drawings or interior design detail drawings, make the most informed decisions with our comprehensive UL assemblies directory and UL assembly details. If there is a penetration in the ceiling of a fire resistance-rated assembly from any wide variety of construction products found in these assemblies, its fire resistance rating can be potentially compromised. Find the right fire-rated assemblies and design details drawings for your architectural plans. Wall Assemblies. Use these instructions to create your UL Product iQ account and search the certification database for UL fire-rated assemblies, designs or systems. There are several other resources to help you in choosing the correct fire rated assembly for your project. Fast Evaluate certified assemblies in just a few clicks How to use the UL Certifications Directory to Search for fire rated Wall, Floor, Roof, and Structural Assemblies Online The UL Certification Mark on exterior wall assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements and is a key differentiator for products within the exterior wall assembly market. Guidelines for finding designs can be located HERE. Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire-rated ceiling assembly. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. wide, minimum 7/16 in. More detailed information on the test assembly requirements and the rating criteria is provided in UL 263/ASTM E119/ULC S101. The fire-protective rated Uninsulated Ventilation Duct Assemblies and corresponding certification program were created for ventilation duct assemblies evaluated to the requirements of ISO 6944 that may not achieve an insulation rating and are for use in applications where an insulation rating (thermal protection) is not required. Nonbearing Wall Rating — 3 HR. Assemblies Directory & Design Details. Please select one of the following databases: Feb 9, 2021 · blies to be fire-resistance rated in accordance with standard fire tests. On-demand Webinar 5G and 802. You can search the UL database of fire rated assemblies here. is required for the project. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances Wall Assemblies. wide, applied horizontally as the outer layer to one side of the assembly. Feb 16, 2024 · each product category and each group of assemblies. USG offers professionals a complete set of architectural drawings for planning and estimation. Metallic outlet boxes for use in fire-rated wall assemblies include single and double gang metallic outlet and switch boxes equipped with “What is included in a UL fire rated assembly?” is a question that comes up on a regular basis. S. The assembly is tested with 25-gauge steel studs at 24” o. L550 August 14, 2020 Unrestrained Assembly Rating — 1 Hr. Below will instruct you on how to search for UL-rated assemblies with a high degree of specificity Jul 9, 2021 · A: The finish rating is an optional, supplemental metric that is separate from the hourly rating of the assembly. Visit Dec 29, 2023 · In UL design U419, 5A appears to only modify the outer layer on one side of the assembly. thick structural sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, manufactured with exterior glue, may be applied horizontally or vertically to the Have you ever had a project to where you were trying to find a fire resistant rating for a wall, floor/ceiling, roof/ceiling or structural component? Underwriters Laboratories or UL has numerous proprietary assemblies at you disposal. 28, 2010 - Underwriters Laboratories (UL) announces the launch of the ULtimate Fire Wizard, an Internet-based tool that allows architects, designers and code authorities to quickly identify fire-resistance-rated assembly designs that meet their project specifications. ” Mar 15, 2024 · each product category and each group of assemblies. These designs are identified in the UL Fire Resistance Directory, which is updated yearly and can be referenced at the Underwriters Laboratories website at ul. Certification Database — UL Product iQ® Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. Jun 17, 2011 · This may be a dumb question, then again, maybe not. Estimate materials and find USG equivalents for your building projects. Personalize your account with a custom dashboard, saved searches and tagging features. Our testing services assess compliance to UL Solutions and industry standards, including: UL 263/ASTM E119 & BS476 Fire Resistance Rating; Smoke Leakage Testing; Our advisory services help ensure building owners that exterior wall assemblies will perform as expected and include: Building Envelope Forensic Services; Building Envelope the use of these designs, see Guide Information for Fire-Resistance Ratings - UL 263 (BXUV). Product iQ is free to use but requires a one-time registration. Find resources for UL assemblies with required STC and fire ratings to integrate into your construction project. , 1, 1-1/2 or 2 Hr. Fire-rated assemblies define a in fire-rated assem-blies. In this e-book, you will learn five tips to efficiently and cost-effectively transition from UL 508 to UL/CSA/IEC 61010-2-201 for industrial power supplies. Do you have questions about Assemblies? Supplementary information about Fire and Sound Rated Assemblies including UL Types. The one- and two-hour ratings are intended to describe how long the assembly will maintain its structural capabilities when exposed to fire. Identify layer details and available products. Fire Safety Information Information related to 5/8" Type X Gypsum Wallboard Standards, Testing, and Certification; Leed Contributions Fire-rated assemblies are tested and certified in their entirety. "(As an alternate to Item 5) — 5/8 in. The building code only requires an hourly fire resistance-rating for the assembly. Kevin further elaborated that while the IBC allows for different methods to specify fire resistance, one common method is to use UL Directory listings. During testing, each assembly is loaded to 100 percent of its design load and then exposed to flames to determine its endurance performance. UL iQ™ brings you databases that help you find products that meet your needs with quick, intuitive searches. Pinpoint content with advanced search features that allow you to compare products, search by testing standards and more. Alternate fire-rated assemblies are typically available from multiple manufacturers with similar components and hourly rating. UL evaluates both metallic and nonmetallic outlet and switch boxes for use in fire-resistant rated assemblies, and provides guidance for proper installation in the associated product category guide information pages. Looking for information on UL Certified products? If you specify products, inspect building construction or purchase products that must meet codes or Standards, you can find the information you need in UL's Product Directories. , Working Stress Design Method). Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. The addition of wood structural panels in fire rated gypsum board wall assemblies is permitted as follows: Wood structural panels that are 4 ft. The number to search should begin with the UL Qualification of fire resistance rated assemblies is based upon standard furnace testing that has remained relatively unchanged since the early 20 th century. The fire-resistance rating of a head-of-wall system (HW-D) classifies the ability of the HW-D assembly to confine and isolate fire within a zone comprised of the assembly. This design was evaluated using a load design method other than the Limit States Design Method (e. I can access only one side of the wall. Access information for thousands of UL certified products, components and materials. How do I achieve a fire rating? UL Design W419 for 1- through 4-hour shaftwall systems or UL design V497 for 1- and 2-hour assemblies using Type X gypsum board on one side of minimum 3 ⅝″ steel studs. Depending on the application, wall assemblies may Westbrook Block prides itself on manufacturing UL® Fire-Rated CMU that can be integrated into the design assemblies pictured below. 2. The Guide Information includes specifics concerning alternate materials. Yes. Engineers, product developers and other professionals can use Product iQ® to verify UL certification of products and components, locate UL guide information and search for alternative products they can trust. Information about UL-Listed me-tallic outlet boxes, in-cluding the Guide In-formation, can also be found by accessing UL’s online product certification database at www. g. Oct 28, 2010 · Northbrook, Ill. This means a tighter stud spacing, a heavier gauge or a wider stud is allowed per UL “Guide Information for Fire-resistance Ratings. It is not replacing the entire assembly listed in 5, it just changes one layer out of everything used in item 5. Fire-resistance rated HW-D assemblies are identified in the UL Fire Resistance Directory, which can be found at the Underwriters Laboratories website at ul. u901 x902 u904 u905 u906 u910 u912 u913 u914 Can plywood panels be added to a fire-resistance rated wall assembly to enhance structural stability? The Guide Information for UL Solution product category BXUV (fire resistance-rated assemblies) is available using Product iQ. View Resources Underwriters Laboratories of Canada ULC…Working for a safer world Fire Resistance Design Requirements for Canada Canadian Model Codes require fire resistance designs to meet the requirements of CAN/ULC‐ UL U425 For Exterior Walls, Ratings Applicable For Exposure To Fire On Interior Face Only Bearing Wall Rating – 3/4 Hr. 1 and others. c. The CDPH Standard Method is referenced by some of the most widely used green building rating systems and codes, including LEED, IgCC, CalGreen, ASHRAE 189. 11ad: mmWave Regulatory Testing - Challenges and Solutions Exterior Fire-Resistance Rated Walls For more information visit www. thick, 24 to 54 in. Apr 26, 2021 · As an architect sometimes you will be tasked to find a UL-rated assembly for a project. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States Why is UL replacing the UL iQ databases for Plastics, Appliance Wiring Material and Wire and Cable? Product iQ is one of several initiatives designed to meet the growing demands of a digital world. The contract documents often contain just the Underwriters Laboratories, Inc. The UL Evaluation Report, an additional differentiator, provides The contractor must construct the UL fire-rated design according to the products approved and tested per the assembly description. com. These include door assemblies, window assemblies, skylights, louvers and shutters. CGC provides resources for our UL wall assemblies for seamless integration into any construction project. , Canada and the rest of the world. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. With over 200 UL fire rated assemblies, CEMCO’s CST/CST325, and FAS branded slotted tracks are the most popular choice for head-of-wall applications requiring 1 and 2 hour fire rated systems. This enables manufacturers to make an investment in a product emissions test that meets a broad range of requirements. The intuitive guided keyword search allows you to search by almost any criteria in one field. For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7. fire ratings. For additional information on USG fire-rated assemblies, CAD, BIM content and specifications, %PDF-1. The platform is designed to create value, support transformation and evolve with changing needs. 11ad: mmWave Regulatory Testing - Challenges and Solutions Only products which bear UL's Mark are considered Certified. Where do you start the search? UL books, drywall manufacturer reference documents (USG), or previous projects are places to start, but there is a better way. Aug 7, 2020 · Bearing Wall Rating — 3 HR. thick oriented strand board (OSB) or 15/32 in. I have a wall which is required to be one-hour rated. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States Restrained Assembly Ratings — 1, 1½, 2 or 3 Hr Unrestrained Assembly Ratings — ¾, 1, 1½, 2 or 3 Hr Beam - Min W6x16 or W8x28 , Joist - 10K1 or 16K2 min, or 12K3 or 12K5 min size P732 P734 Restrained Assembly Ratings — ¾, 1, 1½ or 2 Hr Unrestrained Assembly Ratings — ¾, 1, 1½ or 2 Hr Nov 16, 2022 · 1. Find Revit and CAD files for STC and fire rated UL assemblies. BuildSteel - A Guide to Fire and Acoustic Data for Cold-Formed Steel Floor, Wall and Roof Assemblies; UL® Fire Rating Assembly Look-Up; See below links for UL Design Listings or Intertek fire-rated designs: ProSTUD Approved UL Listings - UL R19331; RC Deluxe Approved UL Listings - UL R19331; MaxTrak Full UL Joint System Listing - UL R26034-XHLI How do I find fire rated walls, floors beams and columns? Most assemblies can be found by searching with specific parameters using the UL Product iQ TM online tool. Fire Rated Assemblies Use our AGDesignLibrary tool to search our database of UL approved fire rated assemblies. The contractor should facilitate and submit a UL rated assembly of the same hourly The Architect of Record and Engineer of Record should be able to tell you which UL file No. The AG Design Library is a robust tool to help you quickly find fire and sound rated assembly information: Then click on the Search button, and your results will be displayed below. vupylocychsjikyqgmnkugcedozuvqdzoppvxnzjfvkjofde